Compare APC by Schneider Electric – SRT3000RMXLW-IEC vs APC by Schneider Electric – BN1500M2-CA Specifications

SRT3000RMXLW-IEC BN1500M2-CA
Product Program Category
Uninterruptible Power Supplies Uninterruptible Power Supplies
Type
Ac-output UPS Ac-output UPS
Brand Name
APC by Schneider Electric APC by Schneider Electric
Model Name
APC Smart-UPS SRT 3000VA RM 208/230V IEC Back UPS PRO BN 1500VA 10 Outlets 2 USB Charging Ports AVR LCD interface Canada
Model Number
SRT3000RMXLW-IEC BN1500M2-CA
UPC
731,304,320,074 731304335900
CB Model Identifier
ES_22220_SRT3000RMXLW-IEC_02012019172814_2094620 ES_22220_BN1500M2-CA_02132019054126_6486005
Meets ENERGY STAR Most Efficient 2024 Criteria
No No
ENERGY STAR Partner
Schneider Electric Schneider Electric
Product Category
Uninterruptible Power Supplies Uninterruptible Power Supplies
Additional Model Information
APC Smart-UPS SRT 3000VA RM 208/230V IEC Factory Serviced,SRT3000RXWIECW,; Std Exch APC Smart-UPS SRT 3000VA RM 208/230V IEC,SRT3000RXWIECQ, Back UPS PRO BN 1500VA 10 Outlets 2 USB Charging Ports AVR LCD interface Canada Factory Serviced,BN1500M2-CAW,; Std Exch Back UPS PRO BN 1500VA 10 Outlets 2 USB Charging Ports AVR LCD interface Canada,BN1500M2-CAQ,
Date Available On Market
October 26, 2015 April 4, 2018
Date Certified
December 28, 2018 February 12, 2019
Markets
United States, Canada Canada
Power Conversion Mechanism
Static Static
Minimum Configuration Tested Model Number
SRT3000RMXLW-IEC BN1500M2
Active Output Power Rating Minimum Configuration (W)
2,700 900
Apparent Output Power Rating Minimum Configuration (VA)
3,000 1500
Topology (ac)
Multi-Mode Double Conversion Line Interactive
Topology and Product Type Combined
ac - Other ac Line Interactive (VI)
Application
Commercial Consumer
Rated Input Voltage (V rms)
208-240 120-120
Rated Input Frequency (Hz)
50-60 60-60
Rated Output Voltage (V)
208-240 120-120
Rated Output Frequency (Hz)
50-60 60-60
Rack Mountable
Yes No
Rack Mount Height (U)
2 N/A
Height (mm)
85 260
Width (mm)
432 100
Depth (mm)
635 368
Total Number of Outlets
8 10
Number of Battery Backup and Surge Protected Outlets
8 6
Number of Surge Protected Only Outlets
0 4
Normal Mode(s) Input Dependency Characteristic (ac)
Voltage and Frequency Dependent,Voltage and Frequency Independent Voltage and Frequency Dependent
Modular UPS
No No
Number of Normal Modes
Multiple-normal-mode Single-normal-mode
Default Normal Mode (ac)
Voltage and Frequency Independent Voltage and Frequency Dependent
Test Input Voltage (V rms)
230 120
Test Input Frequency (Hz)
50 60
Test Output Voltage (V)
230 120
Test Output Frequency (Hz)
50 60
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)
55 3.064
Total Input Power in W at 0% Load Min Config Highest Dependency (ac)
45 N/A
Efficiency at 25% Load Min Config Lowest Dependency (ac)
90 98.5
Efficiency at 25% Load Min Config Highest Dependency (ac)
94 N/A
Efficiency at 50% Load Min Config Lowest Dependency (ac)
93 99
Efficiency at 50% Load Min Config Highest Dependency (ac)
97 N/A
Efficiency at 75% Load Min Config Lowest Dependency (ac)
93 99.1
Efficiency at 75% Load Min Config Highest Dependency (ac)
97 N/A
Efficiency at 100% Load Min Config Lowest Dependency (ac)
93 99.1
Efficiency at 100% Load Min Config Highest Dependency (ac)
98 N/A
Weighted Efficiency Calc Min Config Lowest Dependency
93 99
Weighted Efficiency Calc Min Config Highest Dependency
97 N/A
Minimum Configuration Input Power Factor Lowest-Input Dependency
1 1
Minimum Configuration Input Power Factor Highest-Input Dependency
1 N/A
Efficiency (%)
93 99
Modular UPS Module Tested Model Number
N/A N/A
Energy Storage Mechanism
Battery Battery
Energy Storage System Technology
Valve Regulated Lead-acid Battery Valve Regulated Lead-acid Battery
Energy Storage System Configuration
Integral Integral
Energy Storage System Removable to Another Room
No No
Energy Storage System Runtime at 100% Load (min.)
4 3
Energy Storage System Runtime at 50% Load (min.)
12 11
Energy Storage System Warranty (yrs)
2 3
Energy Storage System Information URL
http://www.apc.com/shop/us/en/products/P-APCRBC152 http://www.apc.com/shop/us/en/products/P-APCRBC161
Battery Recycling URL
http://www.apc.com/company/us/en/sustainability/recycling-options/ http://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Network Connections Available
Serial Port,USB Port USB Port
Communication Protocols
Other,Modbus RTU Other
Communication Protocol Other
USB Power Summary, Micro-Link, Simple Signaling USB Power Summary
Manufacturer Take Back Program
Yes Yes
Manufacturer Take Back Program URL
http://www.apc.com/company/us/en/sustainability/recycling-options/ http://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Model Web Page URL
http://www.apc.com/shop/us/en/products/P-SRT3000RMXLW-IEC http://www.apc.com/shop/us/en/products/P-BN1500M2-CA
Test Method Guidelines
http://www.apc.com/company/us/en/sustainability/energy-efficiency/ http://www.apc.com/us/en/who-we-are/sustainability/
Date Qualified
December 28, 2018 February 12, 2019