Compare CyberPower – PR2000RTXL2U vs CyberPower – OL12KRTHD Specifications

PR2000RTXL2U OL12KRTHD
ENERGY STAR Partner
Cyber Power Systems, Inc. Cyber Power Systems, Inc.
Product Category
Uninterruptible Power Supplies Uninterruptible Power Supplies
Type
Ac-output UPS Ac-output UPS
Brand Name
CyberPower CyberPower
Model Name
PR2000RTXL2U OL12KRTHD
Model Number
PR2000RTXL2U OL12KRTHD
Additional Model Information
PR2000RT2U JP,PR2000RT2U JP,; PR2000RT2U,PR2000RT2U,; PR2000RT2UC,PR2000RT2UC,; PR2000RT2UCN,PR2000RT2UCN,; PR2000RTXL2UC,PR2000RTXL2UC,; PR2000RTXL2UCN,PR2000RTXL2UCN, OL12KRTHDHW,OL12KRTHDHW,; OL12KRTHDHWTAA,OL12KRTHDHWTAA,; OL12KRTHDHWTW,OL12KRTHDHWTW,; OL12KRTHDIEC,OL12KRTHDIEC,; OL12KRTHDIECTAA,OL12KRTHDIECTAA,; OL12KRTHDIECTW,OL12KRTHDIECTW,; OL12KRTHDS,OL12KRTHDS,; OL12KRTHDSHW,OL12KRTHDSHW,; OL12KRTHDSHWTAA,OL12KRTHDSHWTAA,; OL12KRTHDSIEC,OL12KRTHDSIEC,; OL12KRTHDSIECTAA,OL12KRTHDSIECTAA,; OL12KRTHDSTAA,OL12KRTHDSTAA,; OL12KRTHDTAA,OL12KRTHDTAA,; OL12KRTHDTW,OL12KRTHDTW,
Date Available On Market
July 1, 2018 August 1, 2022
Date Certified
June 8, 2018 September 6, 2022
Markets
United States, Taiwan, Japan, Canada United States, Canada
CB Model Identifier
ES_1095904_PR2000RTXL2U_06212018110131_8891341 ES_1095904_OL12KRTHD_100520220157544_2601353
Meets ENERGY STAR Most Efficient 2024 Criteria
No No
Power Conversion Mechanism
Static Static
Minimum Configuration Tested Model Number
PR2000RTXL2U OL12KRTHD
Active Output Power Rating Minimum Configuration (W)
2,000 10000
Apparent Output Power Rating Minimum Configuration (VA)
2,000 12000
Topology (ac)
Line Interactive Double Conversion
Topology and Product Type Combined
ac Line Interactive (VI) ac - Double Conversion (VFI)
Application
Consumer Data Center,Consumer,Commercial
Rated Input Voltage (V rms)
100-125 200-240
Rated Input Frequency (Hz)
50-60 50-60
Rated Output Voltage (V)
100-125 200-240
Rated Output Frequency (Hz)
50-60 50-60
Rack Mountable
Yes Yes
Height (mm)
87 173
Width (mm)
433 433
Depth (mm)
500 720
Normal Mode(s) Input Dependency Characteristic (ac)
Voltage Independent Voltage and Frequency Independent,Voltage and Frequency Dependent
Modular UPS
No No
Number of Normal Modes
Single-normal-mode Multiple-normal-mode
Default Normal Mode (ac)
Voltage Independent Voltage and Frequency Independent
Test Input Voltage (V rms)
120 240
Test Input Frequency (Hz)
60 60
Test Output Voltage (V)
120 240
Test Output Frequency (Hz)
60 60
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)
6 87.66
Efficiency at 25% Load Min Config Lowest Dependency (ac)
98 93.5
Efficiency at 50% Load Min Config Lowest Dependency (ac)
98 94.8
Efficiency at 75% Load Min Config Lowest Dependency (ac)
98 94.6
Efficiency at 100% Load Min Config Lowest Dependency (ac)
98 94.4
Weighted Efficiency Calc Min Config Lowest Dependency
98 94.6
Efficiency (%)
98 94.6
Modular UPS Module Tested Model Number
N/A N/A
Energy Storage Mechanism
Battery Battery
Energy Storage System Technology
Valve Regulated Lead-acid Battery Valve Regulated Lead-acid Battery
Energy Storage System Configuration
Integral Integral
Energy Storage System Removable to Another Room
N/A No
Energy Storage System Runtime at 100% Load (min.)
4 2
Energy Storage System Runtime at 50% Load (min.)
13 7
Energy Storage System Warranty (yrs)
3 3
Energy Storage System Information URL
N/A N/A
Network Connections Available
Serial Port,Ethernet,USB Port Serial Port,Other,USB Port
Communication Protocols
HTTP,HTTPS,Other,SNMP (v1, 2 or 3) HTTP,HTTPS,SNMP (v1, 2 or 3)
Communication Protocol Other
TCP/IP, UDP N/A
Manufacturer Take Back Program
Yes Yes
Model Web Page URL
N/A http://www.cyberpowersystems.com/
Test Method Guidelines
N/A N/A
Date Qualified
June 8, 2018 September 6, 2022