Compare CyberPower – ST900U vs CyberPower – OL10KRTHD Specifications

ST900U OL10KRTHD
ENERGY STAR Partner
Cyber Power Systems, Inc. Cyber Power Systems, Inc.
Product Category
Uninterruptible Power Supplies Uninterruptible Power Supplies
Type
Ac-output UPS Ac-output UPS
Brand Name
CyberPower CyberPower
Model Name
ST900U OL10KRTHD
Model Number
ST900U OL10KRTHD
Date Available On Market
June 15, 2018 August 1, 2022
Date Certified
April 11, 2018 September 6, 2022
Markets
United States United States, Canada
CB Model Identifier
ES_1095904_ST900U_05202018130758_1678289 ES_1095904_OL10KRTHD_100520220156751_5746009
Meets ENERGY STAR Most Efficient 2024 Criteria
No No
Power Conversion Mechanism
Static Static
Minimum Configuration Tested Model Number
SX950U OL12KRTHD
Active Output Power Rating Minimum Configuration (W)
500 10000
Apparent Output Power Rating Minimum Configuration (VA)
900 12000
Topology (ac)
Passive Standby Double Conversion
Topology and Product Type Combined
Alternating Current (ac) - Offline (VFD) ac - Double Conversion (VFI)
Application
Consumer Data Center,Consumer,Commercial
Rated Input Voltage (V rms)
120-120 200-240
Rated Input Frequency (Hz)
50-60 50-60
Rated Output Voltage (V)
120-120 200-240
Rated Output Frequency (Hz)
50-60 50-60
Rack Mountable
No Yes
Height (mm)
310 173
Width (mm)
178 433
Depth (mm)
80 720
Normal Mode(s) Input Dependency Characteristic (ac)
Voltage and Frequency Dependent Voltage and Frequency Independent,Voltage and Frequency Dependent
Modular UPS
No No
Number of Normal Modes
Single-normal-mode Multiple-normal-mode
Default Normal Mode (ac)
Voltage and Frequency Dependent Voltage and Frequency Independent
Test Input Voltage (V rms)
120 240
Test Input Frequency (Hz)
60 60
Test Output Voltage (V)
120 240
Test Output Frequency (Hz)
60 60
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)
3 87.66
Efficiency at 25% Load Min Config Lowest Dependency (ac)
97 93.5
Efficiency at 50% Load Min Config Lowest Dependency (ac)
99 94.8
Efficiency at 75% Load Min Config Lowest Dependency (ac)
99 94.6
Efficiency at 100% Load Min Config Lowest Dependency (ac)
99 94.4
Weighted Efficiency Calc Min Config Lowest Dependency
98 94.6
Efficiency (%)
98 94.6
Modular UPS Module Tested Model Number
N/A N/A
Energy Storage Mechanism
Battery Battery
Energy Storage System Technology
Valve Regulated Lead-acid Battery Valve Regulated Lead-acid Battery
Energy Storage System Configuration
Integral Integral
Energy Storage System Removable to Another Room
N/A No
Energy Storage System Runtime at 100% Load (min.)
2 2
Energy Storage System Runtime at 50% Load (min.)
8 7
Energy Storage System Warranty (yrs)
3 3
Energy Storage System Information URL
N/A N/A
Network Connections Available
USB Port Serial Port,Other,USB Port
Communication Protocols
None HTTP,HTTPS,SNMP (v1, 2 or 3)
Manufacturer Take Back Program
No Yes
Model Web Page URL
N/A http://www.cyberpowersystems.com/
Test Method Guidelines
N/A N/A
Date Qualified
April 11, 2018 September 6, 2022