Compare Delfield – GAR1P-GH vs Delfield – GARRT2P-GS Specifications

GAR1P-GH GARRT2P-GS
ENERGY STAR Partner
The Delfield Company (A division of Welbilt) The Delfield Company (A division of Welbilt)
Product Category
Commercial Refrigerators and Freezers Commercial Refrigerators and Freezers
Type
Vertical Transparent Door Refrigerator Vertical Transparent Door Refrigerator
Brand Name
Delfield Delfield
Model Name
GAR1P-GH GARRT2P-GS
Model Number
GAR1P-GH GARRT2P-GS
Additional Model Information
,G*R1P-GH********,; ,GAR1P-GH********, ,G*RRT2P-GS******,; ,GARRT2P-GS******,
Date Available On Market
April 1, 2017 April 1, 2017
Date Certified
January 27, 2017 August 22, 2017
Markets
United States, Canada United States, Canada
CB Model Identifier
ES_42794_GCR1P-GH_01252017185709_6106073 ES_42794_CSRRT2P-GS_07252017100515_443384
Meets ENERGY STAR Most Efficient 2024 Criteria
No No
Configuration (Vertical/Chest)
Vertical Vertical
Product Description
Glass Dual Door Commercial Refrigerator Transparent Door Refrigerator Cabinet
Defrost Type
Automatic Automatic
Number of glass doors
2 2
Number of solid doors
0 2
Number of Doors
2 4
Door Opening Orientation (Hinged/Sliding)
Hinged Hinged
Volume
21.46 cu. ft. / 0.61 cu. m. 80.06 cu. ft. / 2.27 cu. m.
Mixed Door Cabinet: Glass Door Volume
21.46 cu. ft. / 0.61 cu. m. 80.06 cu. ft. / 2.27 cu. m.
Mixed Door Cabinet: Solid Door Volume
0 cu. ft. / 0.00 cu. m. 0 cu. ft. / 0.00 cu. m.
Height
80 inches / 203.20 cm 89 inches / 226.06 cm
Width
27.5 inches / 69.85 cm 66 inches / 167.64 cm
Depth
32.5 inches / 82.55 cm 34 inches / 86.36 cm
Energy Use (Daily Energy Consumption) (kWh/day)
1.660 kWh/day 5.230 kWh/day
Refrigerant Type
R-290 R-290
Date Qualified
January 27, 2017 August 22, 2017
Number of Transparent Doors
2 2
Number of Drawers
0 0
Mixed Door Cabinet: Transparent Door Volume
21.46 cu. ft. / 0.61 cu. m. 80.06 cu. ft. / 2.27 cu. m.
Total Display Area
0 sq. ft. / 0.00 sq. m. 0 sq. ft. / 0.00 sq. m.
Reported Daily Energy Consumption (kWh/day)
1.660 kWh/day 5.230 kWh/day
Refrigerant with GWP
R-290 (GWP:3 | Lower GWP) R-290 (GWP:3 | Lower GWP)