Compare Schneider Electric – GVSUPS20KGS vs Schneider Electric – GVL300K500DS Specifications

GVSUPS20KGS GVL300K500DS
ENERGY STAR Partner
Schneider Electric Schneider Electric
Product Category
Uninterruptible Power Supplies Uninterruptible Power Supplies
Type
Ac-output UPS Ac-output UPS
Brand Name
Schneider Electric Schneider Electric
Model Name
Galaxy VS 20kW 480V w/o Batteries, Start-up 5x8 Galaxy VL UPS 300 scalable to 500 kW 400/480VStart-up 5x8
Model Number
GVSUPS20KGS GVL300K500DS
Additional Model Information
,GVSUPS20KG, Galaxy VL UPS 300 scalable to 500 kW, 400/480V,GVL300K500D,
Date Available On Market
March 18, 2019 April 3, 2021
Date Certified
July 27, 2018 July 6, 2021
Markets
United States, Canada United States, Canada
CB Model Identifier
ES_22220_GVSUPS20KGS_09122018183216_7136963 ES_22220_GVL300K500DS_071320211429578_7615416
Meets ENERGY STAR Most Efficient 2024 Criteria
No No
Power Conversion Mechanism
Static Static
Minimum Configuration Tested Model Number
GVSUPS20KGS GVL200K500DS
Active Output Power Rating Minimum Configuration (W)
20,000 200000
Apparent Output Power Rating Minimum Configuration (VA)
20,000 200000
Maximum Configuration Tested Model Number
GVSUPS100KGS GVL500KDS
Active Output Power Rating Maximum Configuration (W)
100,000 500000
Topology (ac)
Multi-Mode Double Conversion Multi-Mode Double Conversion
Topology and Product Type Combined
ac - Other ac - Other
Application
Data Center Data Center
Rated Input Voltage (V rms)
480-480 380-480
Rated Input Frequency (Hz)
60-60 50-60
Rated Output Voltage (V)
480-480 380-480
Rated Output Frequency (Hz)
60-60 50-60
Rack Mountable
No No
Height (mm)
1,485 1970
Width (mm)
521 850
Depth (mm)
847 925
Normal Mode(s) Input Dependency Characteristic (ac)
Voltage and Frequency Dependent,Voltage and Frequency Independent Voltage and Frequency Independent,Voltage and Frequency Dependent
Modular UPS
No Yes
Number of Normal Modes
Multiple-normal-mode Multiple-normal-mode
Default Normal Mode (ac)
Voltage and Frequency Independent Voltage and Frequency Independent
Test Input Voltage (V rms)
480 480
Test Input Frequency (Hz)
60 60
Test Output Voltage (V)
480 480
Test Output Frequency (Hz)
60 60
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)
246 852.12
Total Input Power in W at 0% Load Min Config Highest Dependency (ac)
153 429.14
Efficiency at 25% Load Min Config Lowest Dependency (ac)
93 96.3
Efficiency at 25% Load Min Config Highest Dependency (ac)
97 98.9
Efficiency at 50% Load Min Config Lowest Dependency (ac)
96 97.1
Efficiency at 50% Load Min Config Highest Dependency (ac)
98 99.3
Efficiency at 75% Load Min Config Lowest Dependency (ac)
96 97.2
Efficiency at 75% Load Min Config Highest Dependency (ac)
99 99.4
Efficiency at 100% Load Min Config Lowest Dependency (ac)
97 97.2
Efficiency at 100% Load Min Config Highest Dependency (ac)
99 99.5
Weighted Efficiency Calc Min Config Lowest Dependency
95 96.9
Weighted Efficiency Calc Min Config Highest Dependency
98 99.2
Minimum Configuration Input Power Factor Lowest-Input Dependency
1 1
Minimum Configuration Input Power Factor Highest-Input Dependency
1 0.99
Total Input Power in W at 0% Load Max Config Lowest Dependency (ac)
0 1952.82
Total Input Power in W at 0% Load Max Config Highest Dependency (ac)
0 899.06
Efficiency at 25% Load Max Config Lowest Dependency (ac)
96 96.4
Efficiency at 25% Load Max Config Highest Dependency (ac)
99 99
Efficiency at 50% Load Max Config Lowest Dependency (ac)
97 97.1
Efficiency at 50% Load Max Config Highest Dependency (ac)
99 99.3
Efficiency at 75% Load Max Config Lowest Dependency (ac)
97 97.2
Efficiency at 75% Load Max Config Highest Dependency (ac)
99 99.4
Efficiency at 100% Load Max Config Lowest Dependency (ac)
97 97.1
Efficiency at 100% Load Max Config Highest Dependency (ac)
99 99.4
Weighted Efficiency Calc Max Config Lowest Dependency
97 96.9
Weighted Efficiency Calc Max Config Highest Dependency
99 99.3
Maximum Configuration Input Power Factor Lowest-Input Dependency
1 1
Maximum Configuration Input Power Factor Highest-Input Dependency
1 1
Efficiency (%)
96 96.9
Modular UPS Module Tested Model Number
N/A 0G-PM50KD2
Energy Storage Mechanism
Battery Battery
Energy Storage System Technology
Valve Regulated Lead-acid Battery Valve Regulated Lead-acid Battery
Energy Storage System Configuration
Separate Enclosure Separate Enclosure
Energy Storage System Removable to Another Room
Yes Yes
Energy Storage System Runtime at 100% Load (min.)
N/A N/A
Energy Storage System Runtime at 50% Load (min.)
N/A N/A
Energy Storage System Warranty (yrs)
N/A N/A
Energy Storage System Information URL
0 N/A
Battery Recycling URL
http://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp https://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Network Connections Available
Serial Port,Ethernet Serial Port,Ethernet
Communication Protocols
Modbus TCP,HTTPS,Other,HTTP,SNMP (v1, 2 or 3),Modbus RTU HTTP,HTTPS,Modbus TCP,SNMP (v1, 2 or 3),Modbus RTU
Communication Protocol Other
BACnet/IP N/A
Manufacturer Take Back Program
Yes Yes
Manufacturer Take Back Program URL
http://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp https://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Model Web Page URL
http://www.apc.com/shop/us/en/products/P-GVSUPS20KGS https://www.apc.com/shop/us/en/products/P-GVL300K500DS
Test Method Guidelines
0 https://www.apc.com/us/en/who-we-are/sustainability/
Date Qualified
July 27, 2018 July 6, 2021