Compare Schneider Electric – GVSUPS50KGS vs Schneider Electric – SRYL5K15XLT18 Specifications

GVSUPS50KGS SRYL5K15XLT18
ENERGY STAR Partner
Schneider Electric Schneider Electric
Product Category
Uninterruptible Power Supplies Uninterruptible Power Supplies
Type
Ac-output UPS Ac-output UPS
Brand Name
Schneider Electric Schneider Electric
Model Name
Galaxy VS 50kW 480V w/o Batteries, Start-up 5x8 APC Smart-UPS Modular Ultra 5kW Scalable to 15kWN+1 Redundant, Tower, 120+208/240V, 18U Rack
Model Number
GVSUPS50KGS SRYL5K15XLT18
Additional Model Information
,GVSUPS50KG, APC Smart-UPS Modular Ultra 5kW Scalable to 15kW N+1 Redundant, Tower, 120+208/240V, 18U Rack Factory Serviced,SRYL5K15XLT18W,; Std Exch APC Smart-UPS Modular Ultra 5kW Scalable to 15kW N+1 Redundant, Tower, 120+208/240V, 18U Rack,SRYL5K15XLT18Q,
Date Available On Market
March 18, 2019 October 3, 2022
Date Certified
July 27, 2018 August 9, 2022
Markets
United States, Canada United States, Canada
CB Model Identifier
ES_22220_GVSUPS50KGS_09122018183041_7041346 ES_22220_SRYL5K15XLT18_080220221355930_3586641
Meets ENERGY STAR Most Efficient 2024 Criteria
No No
Power Conversion Mechanism
Static Static
Minimum Configuration Tested Model Number
GVSUPS20KGS SRYL5K15RMXLT
Active Output Power Rating Minimum Configuration (W)
20,000 5000
Apparent Output Power Rating Minimum Configuration (VA)
20,000 5000
Maximum Configuration Tested Model Number
GVSUPS100KGS SRYL15K15RMXLT
Active Output Power Rating Maximum Configuration (W)
100,000 15000
Topology (ac)
Multi-Mode Double Conversion Multi-Mode Double Conversion
Topology and Product Type Combined
ac - Other ac - Other
Application
Data Center Commercial
Rated Input Voltage (V rms)
480-480 208-240
Rated Input Frequency (Hz)
60-60 50-60
Rated Output Voltage (V)
480-480 208-240
Rated Output Frequency (Hz)
60-60 50-60
Rack Mountable
No No
Height (mm)
1,485 925
Width (mm)
521 600
Depth (mm)
847 900
Normal Mode(s) Input Dependency Characteristic (ac)
Voltage and Frequency Dependent,Voltage and Frequency Independent Voltage and Frequency Independent,Voltage and Frequency Dependent
Modular UPS
No Yes
Number of Normal Modes
Multiple-normal-mode Multiple-normal-mode
Default Normal Mode (ac)
Voltage and Frequency Independent Voltage and Frequency Independent
Test Input Voltage (V rms)
480 240
Test Input Frequency (Hz)
60 60
Test Output Voltage (V)
480 240
Test Output Frequency (Hz)
60 60
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)
246 72.4
Total Input Power in W at 0% Load Min Config Highest Dependency (ac)
153 75.2
Efficiency at 25% Load Min Config Lowest Dependency (ac)
93 92.8
Efficiency at 25% Load Min Config Highest Dependency (ac)
97 93.7
Efficiency at 50% Load Min Config Lowest Dependency (ac)
96 94.9
Efficiency at 50% Load Min Config Highest Dependency (ac)
98 96.4
Efficiency at 75% Load Min Config Lowest Dependency (ac)
96 95.1
Efficiency at 75% Load Min Config Highest Dependency (ac)
99 97.4
Efficiency at 100% Load Min Config Lowest Dependency (ac)
97 94.7
Efficiency at 100% Load Min Config Highest Dependency (ac)
99 97.8
Weighted Efficiency Calc Min Config Lowest Dependency
95 94.9
Weighted Efficiency Calc Min Config Highest Dependency
98 97.2
Minimum Configuration Input Power Factor Lowest-Input Dependency
1 1
Minimum Configuration Input Power Factor Highest-Input Dependency
1 1
Total Input Power in W at 0% Load Max Config Lowest Dependency (ac)
0 153.2
Total Input Power in W at 0% Load Max Config Highest Dependency (ac)
0 164.4
Efficiency at 25% Load Max Config Lowest Dependency (ac)
96 94.2
Efficiency at 25% Load Max Config Highest Dependency (ac)
99 95.1
Efficiency at 50% Load Max Config Lowest Dependency (ac)
97 95.5
Efficiency at 50% Load Max Config Highest Dependency (ac)
99 97.1
Efficiency at 75% Load Max Config Lowest Dependency (ac)
97 95.4
Efficiency at 75% Load Max Config Highest Dependency (ac)
99 97.8
Efficiency at 100% Load Max Config Lowest Dependency (ac)
97 94.9
Efficiency at 100% Load Max Config Highest Dependency (ac)
99 98.1
Weighted Efficiency Calc Max Config Lowest Dependency
97 95.1
Weighted Efficiency Calc Max Config Highest Dependency
99 96.8
Maximum Configuration Input Power Factor Lowest-Input Dependency
1 1
Maximum Configuration Input Power Factor Highest-Input Dependency
1 1
Efficiency (%)
96 94.9
Modular UPS Module Tested Model Number
N/A SRYL5KPMT
Energy Storage Mechanism
Battery Battery
Energy Storage System Technology
Valve Regulated Lead-acid Battery Lithium-ion Battery
Energy Storage System Configuration
Separate Enclosure Integral
Energy Storage System Removable to Another Room
Yes No
Energy Storage System Runtime at 100% Load (min.)
N/A 5
Energy Storage System Runtime at 50% Load (min.)
N/A 12
Energy Storage System Warranty (yrs)
N/A 5
Energy Storage System Information URL
0 https://www.apc.com/us/en/product/SRYLBM
Battery Recycling URL
http://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp https://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Network Connections Available
Serial Port,Ethernet Serial Port,Ethernet
Communication Protocols
Modbus TCP,HTTPS,Other,HTTP,SNMP (v1, 2 or 3),Modbus RTU HTTP,HTTPS,Modbus TCP,SNMP (v1, 2 or 3),Modbus RTU
Communication Protocol Other
BACnet/IP N/A
Manufacturer Take Back Program
Yes Yes
Manufacturer Take Back Program URL
http://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp https://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Model Web Page URL
http://www.apc.com/shop/us/en/products/P-GVSUPS50KGS https://www.apc.com/us/en/product/SRYL5K15XLT18
Test Method Guidelines
0 https://www.apc.com/us/en/who-we-are/sustainability/
Date Qualified
July 27, 2018 August 9, 2022

Compare Schneider Electric - GVSUPS50KGS With Other 59 Models

Scroll to Top