Introducing the CyberPower CP1000PFCRM1U, a state-of-the-art Ac-output UPS designed for the modern consumer.
This model, CP1000PFCRM1U, is part of the ENERGY STAR certified products and is brought to you by Cyber Power Systems, Inc..
Key Features:
- UPC: 649532936854
- CB Model Identifier: ES_1095904_CP1000PFCRM1U_011120240810261_4175219
- Meets ENERGY STAR Most Efficient 2024 Criteria: No
- Additional Model Information: CP1200PFCRM1U,CP1200PFCRM1U,; CP1500PFCRM1U,CP1500PFCRM1U,
- Date Available On Market: May 15, 2024
- Date Certified: January 11, 2024
- Markets: United States
- Application: Data Center,Consumer,Commercial
Available in United States markets, the CyberPower CP1000PFCRM1U is the perfect addition to any home, offering both performance and energy efficiency.
Release Date: May 15, 2024 Qualified Date: January 11, 2024
Don't miss out on this high-performance, energy-efficient Ac-output UPS.
Get yours today and enjoy the ultimate viewing experience!
More on CP1000PFCRM1U
Full Specifications of CP1000PFCRM1U
Product Program Category | Uninterruptible Power Supplies |
Type | Ac-output UPS |
Brand Name | CyberPower |
Model Name | CP1000PFCRM1U |
Model Number | CP1000PFCRM1U |
UPC | 649,532,936,854 |
CB Model Identifier | ES_1095904_CP1000PFCRM1U_011120240810261_4175219 |
Meets ENERGY STAR Most Efficient 2024 Criteria | No |
ENERGY STAR Partner | Cyber Power Systems, Inc. |
Product Category | Uninterruptible Power Supplies |
Additional Model Information | CP1200PFCRM1U,CP1200PFCRM1U,; CP1500PFCRM1U,CP1500PFCRM1U, |
Date Available On Market | May 15, 2024 |
Date Certified | January 11, 2024 |
Markets | United States |
Power Conversion Mechanism | Static |
Minimum Configuration Tested Model Number | CP1000PFCRM1U |
Active Output Power Rating Minimum Configuration (W) | 600 |
Apparent Output Power Rating Minimum Configuration (VA) | 1,000 |
Topology (ac) | Line Interactive |
Topology and Product Type Combined | ac Line Interactive (VI) |
Application | Data Center,Consumer,Commercial |
Rated Input Voltage (V rms) | 120-120 |
Rated Input Frequency (Hz) | 60-60 |
Rated Output Voltage (V) | 120-120 |
Rated Output Frequency (Hz) | 60-60 |
Rack Mountable | Yes |
Rack Mount Height (U) | 1 |
Height (mm) | 44 |
Width (mm) | 433 |
Depth (mm) | 389 |
Total Number of Outlets | 6 |
Number of Battery Backup and Surge Protected Outlets | 4 |
Number of Surge Protected Only Outlets | 2 |
Normal Mode(s) Input Dependency Characteristic (ac) | Voltage and Frequency Independent |
Modular UPS | No |
Number of Normal Modes | Single-normal-mode |
Default Normal Mode (ac) | Voltage and Frequency Independent |
Test Input Voltage (V rms) | 120 |
Test Input Frequency (Hz) | 60 |
Test Output Voltage (V) | 120 |
Test Output Frequency (Hz) | 60 |
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac) | 3 |
Efficiency at 25% Load Min Config Lowest Dependency (ac) | 97 |
Efficiency at 50% Load Min Config Lowest Dependency (ac) | 99 |
Efficiency at 75% Load Min Config Lowest Dependency (ac) | 99 |
Efficiency at 100% Load Min Config Lowest Dependency (ac) | 99 |
Weighted Efficiency Calc Min Config Lowest Dependency | 99 |
Minimum Configuration Input Power Factor Lowest-Input Dependency | 1 |
Efficiency (%) | 99 |
Modular UPS Module Tested Model Number | N/A |
Energy Storage Mechanism | Battery |
Energy Storage System Technology | Valve Regulated Lead-acid Battery |
Energy Storage System Configuration | Integral |
Energy Storage System Removable to Another Room | No |
Energy Storage System Runtime at 100% Load (min.) | 2 |
Energy Storage System Runtime at 50% Load (min.) | 11 |
Energy Storage System Warranty (yrs) | 3 |
Energy Storage System Information URL | https://www.cyberpowersystems.com/ |
Battery Recycling URL | https://www.cyberpowersystems.com/faqs/what-should-i-do-with-spent-batteries/ |
Network Connections Available | Serial Port,Ethernet |
Communication Protocols | HTTP,HTTPS,SNMP (v1, 2 or 3) |
Manufacturer Take Back Program | Yes |
Manufacturer Take Back Program URL | https://www.cyberpowersystems.com/faqs/how-do-i-dispose-of-my-ups/ |
Model Web Page URL | http://www.cyberpowersystems.com/ |
Test Method Guidelines | https://www.cyberpowersystems.com/ |
Date Qualified | January 11, 2024 |