Introducing the CyberPower OL1500RT JP, a state-of-the-art Ac-output UPS designed for the modern consumer.
This model, OL1500RT JP, is part of the ENERGY STAR certified products and is brought to you by Cyber Power Systems, Inc..
Key Features:
- Date Available On Market: July 1, 2013
- Date Certified: September 19, 2018
- Markets: United States
- CB Model Identifier: ES_1095904_OL1500RT JP_09192018094642_0402177
- Meets ENERGY STAR Most Efficient 2024 Criteria: No
- Application: Commercial,Consumer
Available in United States markets, the CyberPower OL1500RT JP is the perfect addition to any home, offering both performance and energy efficiency.
Release Date: July 1, 2013 Qualified Date: September 19, 2018
Don't miss out on this high-performance, energy-efficient Ac-output UPS.
Get yours today and enjoy the ultimate viewing experience!
More on OL1500RT JP
Full Specifications of OL1500RT JP
ENERGY STAR Partner | Cyber Power Systems, Inc. |
Product Category | Uninterruptible Power Supplies |
Type | Ac-output UPS |
Brand Name | CyberPower |
Model Name | OL1500RT JP |
Model Number | OL1500RT JP |
Date Available On Market | July 1, 2013 |
Date Certified | September 19, 2018 |
Markets | United States |
CB Model Identifier | ES_1095904_OL1500RT JP_09192018094642_0402177 |
Meets ENERGY STAR Most Efficient 2024 Criteria | No |
Power Conversion Mechanism | Static |
Minimum Configuration Tested Model Number | OL1500RTXL2U |
Active Output Power Rating Minimum Configuration (W) | 1,350 |
Apparent Output Power Rating Minimum Configuration (VA) | 1,500 |
Topology (ac) | Double Conversion |
Topology and Product Type Combined | ac - Double Conversion (VFI) |
Application | Commercial,Consumer |
Rated Input Voltage (V rms) | 100-125 |
Rated Input Frequency (Hz) | 50-60 |
Rated Output Voltage (V) | 100-125 |
Rated Output Frequency (Hz) | 50-60 |
Rack Mountable | Yes |
Rack Mount Height (U) | 2 |
Height (mm) | 88 |
Width (mm) | 433 |
Depth (mm) | 430 |
Normal Mode(s) Input Dependency Characteristic (ac) | Voltage and Frequency Dependent,Voltage and Frequency Independent |
Modular UPS | No |
Number of Normal Modes | Multiple-normal-mode |
Default Normal Mode (ac) | Voltage and Frequency Independent |
Test Input Voltage (V rms) | 120 |
Test Input Frequency (Hz) | 60 |
Test Output Voltage (V) | 120 |
Test Output Frequency (Hz) | 60 |
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac) | 24 |
Efficiency at 25% Load Min Config Lowest Dependency (ac) | 89 |
Efficiency at 50% Load Min Config Lowest Dependency (ac) | 91 |
Efficiency at 75% Load Min Config Lowest Dependency (ac) | 91 |
Efficiency at 100% Load Min Config Lowest Dependency (ac) | 91 |
Weighted Efficiency Calc Min Config Lowest Dependency | 91 |
Efficiency (%) | 91 |
Modular UPS Module Tested Model Number | N/A |
Energy Storage Mechanism | Battery |
Energy Storage System Technology | Valve Regulated Lead-acid Battery |
Energy Storage System Configuration | Integral |
Energy Storage System Removable to Another Room | No |
Energy Storage System Runtime at 100% Load (min.) | 4 |
Energy Storage System Runtime at 50% Load (min.) | 11 |
Energy Storage System Warranty (yrs) | 3 |
Energy Storage System Information URL | http://www.cyberpowersystems.com/ |
Network Connections Available | Serial Port,USB Port,Ethernet |
Communication Protocols | HTTPS,HTTP,SNMP (v1, 2 or 3) |
Manufacturer Take Back Program | Yes |
Model Web Page URL | http://www.cyberpowersystems.com |
Test Method Guidelines | http://www.cyberpowersystems.com/ |
Date Qualified | September 19, 2018 |