PR3000RTXL2UA by CyberPower – Specifications

Introducing the CyberPower PR3000RTXL2UA, a state-of-the-art Ac-output UPS designed for the modern consumer.

This model, PR3000RTXL2UA, is part of the ENERGY STAR certified products and is brought to you by Cyber Power Systems, Inc..

Key Features:

  • Additional Model Information: PR2200RT2U JP,PR2200RT2U JP,; PR2200RT2U,PR2200RT2U,; PR2200RT2UC,PR2200RT2UC,; PR2200RT2UCN,PR2200RT2UCN,; PR2200RTXL2U JP,PR2200RTXL2U JP,; PR2200RTXL2U,PR2200RTXL2U,; PR2200RTXL2UA JP,PR2200RTXL2UA JP,; PR2200RTXL2UA,PR2200RTXL2UA,; PR2200RTXL2UAC,PR2200RTXL2UAC,; PR2200RTXL2UACN,PR2200RTXL2UACN,; PR2200RTXL2UC,PR2200RTXL2UC,; PR2200RTXL2UCN,PR2200RTXL2UCN,; PR3000RT2U JP,PR3000RT2U JP,; PR3000RT2U,PR3000RT2U,; PR3000RT2UC,PR3000RT2UC,; PR3000RT2UCN,PR3000RT2UCN,; PR3000RTXL2U JP,PR3000RTXL2U JP,; PR3000RTXL2U,PR3000RTXL2U,; PR3000RTXL2UA JP,PR3000RTXL2UA JP,; PR3000RTXL2UAC,PR3000RTXL2UAC,; PR3000RTXL2UACN,PR3000RTXL2UACN,; PR3000RTXL2UC,PR3000RTXL2UC,; PR3000RTXL2UCN,PR3000RTXL2UCN,; PRL3000RT2UC,PRL3000RT2UC,; PRL3000RT2UCN,PRL3000RT2UCN,
  • Date Available On Market: August 1, 2018
  • Date Certified: January 17, 2023
  • Markets: United States, Taiwan, Japan, Canada
  • CB Model Identifier: ES_1095904_PR3000RTXL2UA_07292018101208_9128733
  • Meets ENERGY STAR Most Efficient 2024 Criteria: No
  • Application: Consumer

Available in United States, Taiwan, Japan, Canada markets, the CyberPower PR3000RTXL2UA is the perfect addition to any home, offering both performance and energy efficiency.

Release Date: August 1, 2018 Qualified Date: January 17, 2023

Don't miss out on this high-performance, energy-efficient Ac-output UPS.

Get yours today and enjoy the ultimate viewing experience!

Full Specifications of PR3000RTXL2UA

ENERGY STAR PartnerCyber Power Systems, Inc.
Product CategoryUninterruptible Power Supplies
TypeAc-output UPS
Brand NameCyberPower
Model NamePR3000RTXL2UA
Model NumberPR3000RTXL2UA
Additional Model InformationPR2200RT2U JP,PR2200RT2U JP,; PR2200RT2U,PR2200RT2U,; PR2200RT2UC,PR2200RT2UC,; PR2200RT2UCN,PR2200RT2UCN,; PR2200RTXL2U JP,PR2200RTXL2U JP,; PR2200RTXL2U,PR2200RTXL2U,; PR2200RTXL2UA JP,PR2200RTXL2UA JP,; PR2200RTXL2UA,PR2200RTXL2UA,; PR2200RTXL2UAC,PR2200RTXL2UAC,; PR2200RTXL2UACN,PR2200RTXL2UACN,; PR2200RTXL2UC,PR2200RTXL2UC,; PR2200RTXL2UCN,PR2200RTXL2UCN,; PR3000RT2U JP,PR3000RT2U JP,; PR3000RT2U,PR3000RT2U,; PR3000RT2UC,PR3000RT2UC,; PR3000RT2UCN,PR3000RT2UCN,; PR3000RTXL2U JP,PR3000RTXL2U JP,; PR3000RTXL2U,PR3000RTXL2U,; PR3000RTXL2UA JP,PR3000RTXL2UA JP,; PR3000RTXL2UAC,PR3000RTXL2UAC,; PR3000RTXL2UACN,PR3000RTXL2UACN,; PR3000RTXL2UC,PR3000RTXL2UC,; PR3000RTXL2UCN,PR3000RTXL2UCN,; PRL3000RT2UC,PRL3000RT2UC,; PRL3000RT2UCN,PRL3000RT2UCN,
Date Available On MarketAugust 1, 2018
Date CertifiedJanuary 17, 2023
MarketsUnited States, Taiwan, Japan, Canada
CB Model IdentifierES_1095904_PR3000RTXL2UA_07292018101208_9128733
Meets ENERGY STAR Most Efficient 2024 CriteriaNo
Power Conversion MechanismStatic
Minimum Configuration Tested Model NumberPR2200RTXL2UA
Active Output Power Rating Minimum Configuration (W)2,200
Apparent Output Power Rating Minimum Configuration (VA)2,200
Maximum Configuration Tested Model NumberPR3000RTXL2UA
Active Output Power Rating Maximum Configuration (W)3,000
Topology (ac)Line Interactive
Topology and Product Type Combinedac Line Interactive (VI)
ApplicationConsumer
Rated Input Voltage (V rms)100-120
Rated Input Frequency (Hz)50-60
Rated Output Voltage (V)100-120
Rated Output Frequency (Hz)50-60
Rack MountableYes
Rack Mount Height (U)2
Height (mm)87
Width (mm)433
Depth (mm)630
Normal Mode(s) Input Dependency Characteristic (ac)Voltage Independent
Modular UPSNo
Number of Normal ModesSingle-normal-mode
Default Normal Mode (ac)Voltage Independent
Test Input Voltage (V rms)120
Test Input Frequency (Hz)60
Test Output Voltage (V)120
Test Output Frequency (Hz)60
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)4
Efficiency at 25% Load Min Config Lowest Dependency (ac)98
Efficiency at 50% Load Min Config Lowest Dependency (ac)98
Efficiency at 75% Load Min Config Lowest Dependency (ac)98
Efficiency at 100% Load Min Config Lowest Dependency (ac)98
Weighted Efficiency Calc Min Config Lowest Dependency98
Total Input Power in W at 0% Load Max Config Lowest Dependency (ac)5
Efficiency at 25% Load Max Config Lowest Dependency (ac)99
Efficiency at 50% Load Max Config Lowest Dependency (ac)99
Efficiency at 75% Load Max Config Lowest Dependency (ac)99
Efficiency at 100% Load Max Config Lowest Dependency (ac)98
Weighted Efficiency Calc Max Config Lowest Dependency99
Efficiency (%)98
Modular UPS Module Tested Model NumberN/A
Energy Storage MechanismBattery
Energy Storage System TechnologyValve Regulated Lead-acid Battery
Energy Storage System ConfigurationIntegral
Energy Storage System Removable to Another RoomNo
Energy Storage System Runtime at 100% Load (min.)4
Energy Storage System Runtime at 50% Load (min.)11
Energy Storage System Warranty (yrs)3
Energy Storage System Information URLN/A
Network Connections AvailableSerial Port,Ethernet,USB Port
Communication ProtocolsHTTP,HTTPS,Other,SNMP (v1, 2 or 3)
Communication Protocol OtherTCP/IP, UDP
Manufacturer Take Back ProgramYes
Model Web Page URLN/A
Test Method GuidelinesN/A
Date QualifiedJanuary 17, 2023