Introducing the CyberPower SX950U, a state-of-the-art Ac-output UPS designed for the modern consumer.
This model, SX950U, is part of the ENERGY STAR certified products and is brought to you by Cyber Power Systems, Inc..
Key Features:
- Date Available On Market: May 15, 2018
- Date Certified: April 11, 2018
- Markets: United States
- CB Model Identifier: ES_1095904_SX950U_05202018130453_1493920
- Meets ENERGY STAR Most Efficient 2024 Criteria: No
- Application: Consumer
Available in United States markets, the CyberPower SX950U is the perfect addition to any home, offering both performance and energy efficiency.
Release Date: May 15, 2018 Qualified Date: April 11, 2018
Don't miss out on this high-performance, energy-efficient Ac-output UPS.
Get yours today and enjoy the ultimate viewing experience!
Full Specifications of SX950U
ENERGY STAR Partner | Cyber Power Systems, Inc. |
Product Category | Uninterruptible Power Supplies |
Type | Ac-output UPS |
Brand Name | CyberPower |
Model Name | SX950U |
Model Number | SX950U |
Date Available On Market | May 15, 2018 |
Date Certified | April 11, 2018 |
Markets | United States |
CB Model Identifier | ES_1095904_SX950U_05202018130453_1493920 |
Meets ENERGY STAR Most Efficient 2024 Criteria | No |
Power Conversion Mechanism | Static |
Minimum Configuration Tested Model Number | SX950U |
Active Output Power Rating Minimum Configuration (W) | 510 |
Apparent Output Power Rating Minimum Configuration (VA) | 950 |
Topology (ac) | Passive Standby |
Topology and Product Type Combined | Alternating Current (ac) - Offline (VFD) |
Application | Consumer |
Rated Input Voltage (V rms) | 120-120 |
Rated Input Frequency (Hz) | 50-60 |
Rated Output Voltage (V) | 120-120 |
Rated Output Frequency (Hz) | 50-60 |
Rack Mountable | No |
Height (mm) | 310 |
Width (mm) | 178 |
Depth (mm) | 80 |
Normal Mode(s) Input Dependency Characteristic (ac) | Voltage and Frequency Dependent |
Modular UPS | No |
Number of Normal Modes | Single-normal-mode |
Default Normal Mode (ac) | Voltage and Frequency Dependent |
Test Input Voltage (V rms) | 120 |
Test Input Frequency (Hz) | 60 |
Test Output Voltage (V) | 120 |
Test Output Frequency (Hz) | 60 |
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac) | 3 |
Efficiency at 25% Load Min Config Lowest Dependency (ac) | 97 |
Efficiency at 50% Load Min Config Lowest Dependency (ac) | 99 |
Efficiency at 75% Load Min Config Lowest Dependency (ac) | 99 |
Efficiency at 100% Load Min Config Lowest Dependency (ac) | 99 |
Weighted Efficiency Calc Min Config Lowest Dependency | 98 |
Efficiency (%) | 98 |
Modular UPS Module Tested Model Number | N/A |
Energy Storage Mechanism | Battery |
Energy Storage System Technology | Valve Regulated Lead-acid Battery |
Energy Storage System Configuration | Integral |
Energy Storage System Removable to Another Room | N/A |
Energy Storage System Runtime at 100% Load (min.) | 2 |
Energy Storage System Runtime at 50% Load (min.) | 8 |
Energy Storage System Warranty (yrs) | 3 |
Energy Storage System Information URL | N/A |
Network Connections Available | USB Port |
Communication Protocols | None |
Manufacturer Take Back Program | No |
Model Web Page URL | N/A |
Test Method Guidelines | N/A |
Date Qualified | April 11, 2018 |