GXT5-2000IRT2UXL by Liebert – Specifications

Introducing the Liebert GXT5-2000IRT2UXL, a state-of-the-art Ac-output UPS designed for the modern consumer.

This model, GXT5-2000IRT2UXL, is part of the ENERGY STAR certified products and is brought to you by Vertiv Corporation.

Key Features:

  • Additional Model Information: GXT5-2000IRT2UXLA,GXT5-2000IRT2UXLA,; GXT5-2000IRT2UXLB,GXT5-2000IRT2UXLB,; GXT5-2000IRT2UXLE,GXT5-2000IRT2UXLE,
  • Date Available On Market: April 1, 2019
  • Date Certified: April 1, 2019
  • Markets: United States, Taiwan, Japan, Canada
  • CB Model Identifier: ES_1097807_GXT5-2000IRT2UXL_04092019073855_5535743
  • Meets ENERGY STAR Most Efficient 2024 Criteria: No
  • Application: Commercial,Consumer,Data Center

Available in United States, Taiwan, Japan, Canada markets, the Liebert GXT5-2000IRT2UXL is the perfect addition to any home, offering both performance and energy efficiency.

Release Date: April 1, 2019 Qualified Date: April 1, 2019

Don't miss out on this high-performance, energy-efficient Ac-output UPS.

Get yours today and enjoy the ultimate viewing experience!

Full Specifications of GXT5-2000IRT2UXL

ENERGY STAR PartnerVertiv Corporation
Product CategoryUninterruptible Power Supplies
TypeAc-output UPS
Brand NameLiebert
Model NameGXT5-2000IRT2UXL
Model NumberGXT5-2000IRT2UXL
Additional Model InformationGXT5-2000IRT2UXLA,GXT5-2000IRT2UXLA,; GXT5-2000IRT2UXLB,GXT5-2000IRT2UXLB,; GXT5-2000IRT2UXLE,GXT5-2000IRT2UXLE,
Date Available On MarketApril 1, 2019
Date CertifiedApril 1, 2019
MarketsUnited States, Taiwan, Japan, Canada
CB Model IdentifierES_1097807_GXT5-2000IRT2UXL_04092019073855_5535743
Meets ENERGY STAR Most Efficient 2024 CriteriaNo
Power Conversion MechanismStatic
Minimum Configuration Tested Model NumberGXT5-2000IRT2UXL
Active Output Power Rating Minimum Configuration (W)2,000
Apparent Output Power Rating Minimum Configuration (VA)2,000
Topology (ac)Multi-Mode Double Conversion
Topology and Product Type Combinedac - Other
ApplicationCommercial,Consumer,Data Center
Rated Input Voltage (V rms)200-240
Rated Input Frequency (Hz)50-60
Rated Output Voltage (V)200-240
Rated Output Frequency (Hz)50-60
Rack MountableYes
Height (mm)85
Width (mm)430
Depth (mm)470
Normal Mode(s) Input Dependency Characteristic (ac)Voltage and Frequency Dependent,Voltage and Frequency Independent
Modular UPSNo
Number of Normal ModesMultiple-normal-mode
Default Normal Mode (ac)Voltage and Frequency Independent
Test Input Voltage (V rms)230
Test Input Frequency (Hz)50
Test Output Voltage (V)230
Test Output Frequency (Hz)50
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)25
Efficiency at 25% Load Min Config Lowest Dependency (ac)91
Efficiency at 50% Load Min Config Lowest Dependency (ac)93
Efficiency at 75% Load Min Config Lowest Dependency (ac)93
Efficiency at 100% Load Min Config Lowest Dependency (ac)93
Weighted Efficiency Calc Min Config Lowest Dependency93
Minimum Configuration Input Power Factor Lowest-Input Dependency1
Efficiency (%)93
Modular UPS Module Tested Model NumberN/A
Energy Storage MechanismBattery
Energy Storage System TechnologyValve Regulated Lead-acid Battery
Energy Storage System ConfigurationSeparate Enclosure
Energy Storage System Removable to Another RoomNo
Energy Storage System Runtime at 100% Load (min.)3
Energy Storage System Runtime at 50% Load (min.)9
Energy Storage System Warranty (yrs)2
Energy Storage System Information URLhttp://www.enersys.com/ http://www.eastpennunigy.com/
Network Connections AvailableUSB Port,Ethernet
Communication ProtocolsOther
Manufacturer Take Back ProgramNo
Model Web Page URLhttps://www.vertivco.com/en-us/products-catalog/critical-power/uninterruptible-power-supplies-ups/
Test Method GuidelinesN/A
Date QualifiedApril 1, 2019