Introducing the Schneider Electric Galaxy VM 225 kVA UPS Single 480-480 V, 65kAIC,, a state-of-the-art Ac-output UPS designed for the modern consumer.
This model, GVMSB225KG65S, is part of the ENERGY STAR certified products and is brought to you by Schneider Electric.
Key Features:
- UPC: 731304326571
- CB Model Identifier: ES_22220_GVMSB225KG65S_02272019165924_6764375
- Meets ENERGY STAR Most Efficient 2024 Criteria: No
- Additional Model Information: ,GVMSB225KGS,
- Date Available On Market: September 23, 2015
- Date Certified: February 26, 2019
- Markets: United States, Canada
- Application: Data Center
Available in United States, Canada markets, the Schneider Electric Galaxy VM 225 kVA UPS Single 480-480 V, 65kAIC, is the perfect addition to any home, offering both performance and energy efficiency.
Release Date: September 23, 2015 Qualified Date: February 26, 2019
Don't miss out on this high-performance, energy-efficient Ac-output UPS.
Get yours today and enjoy the ultimate viewing experience!
More on GVMSB225KG65S
Full Specifications of GVMSB225KG65S
Product Program Category | Uninterruptible Power Supplies |
Type | Ac-output UPS |
Brand Name | Schneider Electric |
Model Name | Galaxy VM 225 kVA UPS Single 480-480 V, 65kAIC, |
Model Number | GVMSB225KG65S |
UPC | 731,304,326,571 |
CB Model Identifier | ES_22220_GVMSB225KG65S_02272019165924_6764375 |
Meets ENERGY STAR Most Efficient 2024 Criteria | No |
ENERGY STAR Partner | Schneider Electric |
Product Category | Uninterruptible Power Supplies |
Additional Model Information | ,GVMSB225KGS, |
Date Available On Market | September 23, 2015 |
Date Certified | February 26, 2019 |
Markets | United States, Canada |
Power Conversion Mechanism | Static |
Minimum Configuration Tested Model Number | GVMPB225KGS |
Active Output Power Rating Minimum Configuration (W) | 202,500 |
Apparent Output Power Rating Minimum Configuration (VA) | 225,000 |
Topology (ac) | Double Conversion |
Topology and Product Type Combined | ac - Double Conversion (VFI) |
Application | Data Center |
Rated Input Voltage (V rms) | 480-480 |
Rated Input Frequency (Hz) | 50-60 |
Rated Output Voltage (V) | 480-480 |
Rated Output Frequency (Hz) | 50-60 |
Rack Mountable | No |
Height (mm) | 1,970 |
Width (mm) | 1,002 |
Depth (mm) | 854 |
Normal Mode(s) Input Dependency Characteristic (ac) | Voltage and Frequency Dependent,Voltage and Frequency Independent |
Modular UPS | No |
Number of Normal Modes | Multiple-normal-mode |
Default Normal Mode (ac) | Voltage and Frequency Independent |
Test Input Voltage (V rms) | 480 |
Test Input Frequency (Hz) | 60 |
Test Output Voltage (V) | 480 |
Test Output Frequency (Hz) | 60 |
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac) | 1,038 |
Total Input Power in W at 0% Load Min Config Highest Dependency (ac) | 530 |
Efficiency at 25% Load Min Config Lowest Dependency (ac) | 96 |
Efficiency at 25% Load Min Config Highest Dependency (ac) | 99 |
Efficiency at 50% Load Min Config Lowest Dependency (ac) | 96 |
Efficiency at 50% Load Min Config Highest Dependency (ac) | 99 |
Efficiency at 75% Load Min Config Lowest Dependency (ac) | 97 |
Efficiency at 75% Load Min Config Highest Dependency (ac) | 99 |
Efficiency at 100% Load Min Config Lowest Dependency (ac) | 96 |
Efficiency at 100% Load Min Config Highest Dependency (ac) | 100 |
Weighted Efficiency Calc Min Config Lowest Dependency | 96 |
Weighted Efficiency Calc Min Config Highest Dependency | 99 |
Minimum Configuration Input Power Factor Lowest-Input Dependency | 1 |
Minimum Configuration Input Power Factor Highest-Input Dependency | 1 |
Efficiency (%) | 97 |
Modular UPS Module Tested Model Number | N/A |
Energy Storage Mechanism | Battery |
Energy Storage System Technology | Valve Regulated Lead-acid Battery |
Energy Storage System Configuration | Separate Enclosure |
Energy Storage System Removable to Another Room | Yes |
Energy Storage System Runtime at 100% Load (min.) | N/A |
Energy Storage System Runtime at 50% Load (min.) | N/A |
Energy Storage System Warranty (yrs) | N/A |
Energy Storage System Information URL | https://www.apc.com/template/size/apc/sizing_display_options.cfm?option_type=Battery&interface=UPS&famid=483&ups_sku=GVMSB225KG65S |
Battery Recycling URL | https://www.apc.com/company/us/en/sustainability/recycling-options/ |
Network Connections Available | Serial Port,Ethernet |
Communication Protocols | Modbus TCP,HTTPS,HTTP,Modbus RTU |
Communication Protocol Other | SNMP (v1, 2 or 3) |
Manufacturer Take Back Program | Yes |
Manufacturer Take Back Program URL | https://www.apc.com/company/us/en/sustainability/recycling-options/ |
Model Web Page URL | https://www.apc.com/shop/us/en/products/P-GVMSB225KG65S |
Test Method Guidelines | https://www.apc.com/company/us/en/sustainability/energy-efficiency/ |
Date Qualified | February 26, 2019 |
Compare Schneider Electric - GVMSB225KG65S With Other 59 Models
Related Models - GVMSB225KG65S Alternative
- Schneider Electric GVSUPS30KGS