GVSUPS20KGS by Schneider Electric – Specifications

Introducing the Schneider Electric Galaxy VS 20kW 480V w/o Batteries, Start-up 5x8, a state-of-the-art Ac-output UPS designed for the modern consumer.

This model, GVSUPS20KGS, is part of the ENERGY STAR certified products and is brought to you by Schneider Electric.

Key Features:

  • Additional Model Information: ,GVSUPS20KG,
  • Date Available On Market: March 18, 2019
  • Date Certified: July 27, 2018
  • Markets: United States, Canada
  • CB Model Identifier: ES_22220_GVSUPS20KGS_09122018183216_7136963
  • Meets ENERGY STAR Most Efficient 2024 Criteria: No
  • Application: Data Center

Available in United States, Canada markets, the Schneider Electric Galaxy VS 20kW 480V w/o Batteries, Start-up 5x8 is the perfect addition to any home, offering both performance and energy efficiency.

Release Date: March 18, 2019 Qualified Date: July 27, 2018

Don't miss out on this high-performance, energy-efficient Ac-output UPS.

Get yours today and enjoy the ultimate viewing experience!

Full Specifications of GVSUPS20KGS

ENERGY STAR PartnerSchneider Electric
Product CategoryUninterruptible Power Supplies
TypeAc-output UPS
Brand NameSchneider Electric
Model NameGalaxy VS 20kW 480V w/o Batteries, Start-up 5x8
Model NumberGVSUPS20KGS
Additional Model Information,GVSUPS20KG,
Date Available On MarketMarch 18, 2019
Date CertifiedJuly 27, 2018
MarketsUnited States, Canada
CB Model IdentifierES_22220_GVSUPS20KGS_09122018183216_7136963
Meets ENERGY STAR Most Efficient 2024 CriteriaNo
Power Conversion MechanismStatic
Minimum Configuration Tested Model NumberGVSUPS20KGS
Active Output Power Rating Minimum Configuration (W)20,000
Apparent Output Power Rating Minimum Configuration (VA)20,000
Maximum Configuration Tested Model NumberGVSUPS100KGS
Active Output Power Rating Maximum Configuration (W)100,000
Topology (ac)Multi-Mode Double Conversion
Topology and Product Type Combinedac - Other
ApplicationData Center
Rated Input Voltage (V rms)480-480
Rated Input Frequency (Hz)60-60
Rated Output Voltage (V)480-480
Rated Output Frequency (Hz)60-60
Rack MountableNo
Height (mm)1,485
Width (mm)521
Depth (mm)847
Normal Mode(s) Input Dependency Characteristic (ac)Voltage and Frequency Dependent,Voltage and Frequency Independent
Modular UPSNo
Number of Normal ModesMultiple-normal-mode
Default Normal Mode (ac)Voltage and Frequency Independent
Test Input Voltage (V rms)480
Test Input Frequency (Hz)60
Test Output Voltage (V)480
Test Output Frequency (Hz)60
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac)246
Total Input Power in W at 0% Load Min Config Highest Dependency (ac)153
Efficiency at 25% Load Min Config Lowest Dependency (ac)93
Efficiency at 25% Load Min Config Highest Dependency (ac)97
Efficiency at 50% Load Min Config Lowest Dependency (ac)96
Efficiency at 50% Load Min Config Highest Dependency (ac)98
Efficiency at 75% Load Min Config Lowest Dependency (ac)96
Efficiency at 75% Load Min Config Highest Dependency (ac)99
Efficiency at 100% Load Min Config Lowest Dependency (ac)97
Efficiency at 100% Load Min Config Highest Dependency (ac)99
Weighted Efficiency Calc Min Config Lowest Dependency95
Weighted Efficiency Calc Min Config Highest Dependency98
Minimum Configuration Input Power Factor Lowest-Input Dependency1
Minimum Configuration Input Power Factor Highest-Input Dependency1
Total Input Power in W at 0% Load Max Config Lowest Dependency (ac)0
Total Input Power in W at 0% Load Max Config Highest Dependency (ac)0
Efficiency at 25% Load Max Config Lowest Dependency (ac)96
Efficiency at 25% Load Max Config Highest Dependency (ac)99
Efficiency at 50% Load Max Config Lowest Dependency (ac)97
Efficiency at 50% Load Max Config Highest Dependency (ac)99
Efficiency at 75% Load Max Config Lowest Dependency (ac)97
Efficiency at 75% Load Max Config Highest Dependency (ac)99
Efficiency at 100% Load Max Config Lowest Dependency (ac)97
Efficiency at 100% Load Max Config Highest Dependency (ac)99
Weighted Efficiency Calc Max Config Lowest Dependency97
Weighted Efficiency Calc Max Config Highest Dependency99
Maximum Configuration Input Power Factor Lowest-Input Dependency1
Maximum Configuration Input Power Factor Highest-Input Dependency1
Efficiency (%)96
Modular UPS Module Tested Model NumberN/A
Energy Storage MechanismBattery
Energy Storage System TechnologyValve Regulated Lead-acid Battery
Energy Storage System ConfigurationSeparate Enclosure
Energy Storage System Removable to Another RoomYes
Energy Storage System Runtime at 100% Load (min.)N/A
Energy Storage System Runtime at 50% Load (min.)N/A
Energy Storage System Warranty (yrs)N/A
Energy Storage System Information URL0
Battery Recycling URLhttp://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Network Connections AvailableSerial Port,Ethernet
Communication ProtocolsModbus TCP,HTTPS,Other,HTTP,SNMP (v1, 2 or 3),Modbus RTU
Communication Protocol OtherBACnet/IP
Manufacturer Take Back ProgramYes
Manufacturer Take Back Program URLhttp://www.apc.com/us/en/who-we-are/sustainability/recycling-options.jsp
Model Web Page URLhttp://www.apc.com/shop/us/en/products/P-GVSUPS20KGS
Test Method Guidelines0
Date QualifiedJuly 27, 2018

Compare Schneider Electric - GVSUPS20KGS With Other 59 Models

Related Models - GVSUPS20KGS Alternative

Scroll to Top