Introducing the Vertiv ITA-01k00AS1102C00, a state-of-the-art Ac-output UPS designed for the modern consumer.
This model, ITA-01k00AS1102C00, is part of the ENERGY STAR certified products and is brought to you by Vertiv Corporation.
Key Features:
- Additional Model Information: ITA-01k00AL1102C00,ITA-01k00AL1102C00,
- Date Available On Market: August 20, 2020
- Date Certified: September 18, 2020
- Markets: United States, Taiwan, Japan, Canada
- CB Model Identifier: ES_1097807_ITA-01k00AS1102C00_09182020093416_1656296
- Meets ENERGY STAR Most Efficient 2024 Criteria: No
- Application: Data Center,Consumer,Commercial
Available in United States, Taiwan, Japan, Canada markets, the Vertiv ITA-01k00AS1102C00 is the perfect addition to any home, offering both performance and energy efficiency.
Release Date: August 20, 2020 Qualified Date: September 18, 2020
Don't miss out on this high-performance, energy-efficient Ac-output UPS.
Get yours today and enjoy the ultimate viewing experience!
More on ITA-01k00AS1102C00
Full Specifications of ITA-01k00AS1102C00
ENERGY STAR Partner | Vertiv Corporation |
Product Category | Uninterruptible Power Supplies |
Type | Ac-output UPS |
Brand Name | Vertiv |
Model Name | ITA-01k00AS1102C00 |
Model Number | ITA-01k00AS1102C00 |
Additional Model Information | ITA-01k00AL1102C00,ITA-01k00AL1102C00, |
Date Available On Market | August 20, 2020 |
Date Certified | September 18, 2020 |
Markets | United States, Taiwan, Japan, Canada |
CB Model Identifier | ES_1097807_ITA-01k00AS1102C00_09182020093416_1656296 |
Meets ENERGY STAR Most Efficient 2024 Criteria | No |
Power Conversion Mechanism | Static |
Minimum Configuration Tested Model Number | ITA-01k00AS1102C00 |
Active Output Power Rating Minimum Configuration (W) | 1,000 |
Apparent Output Power Rating Minimum Configuration (VA) | 1,000 |
Topology (ac) | Multi-Mode Double Conversion |
Topology and Product Type Combined | ac - Other |
Application | Data Center,Consumer,Commercial |
Rated Input Voltage (V rms) | 220-240 |
Rated Input Frequency (Hz) | 50-50 |
Rated Output Voltage (V) | 220-240 |
Rated Output Frequency (Hz) | 50-50 |
Rack Mountable | Yes |
Height (mm) | 85 |
Width (mm) | 430 |
Depth (mm) | 400 |
Normal Mode(s) Input Dependency Characteristic (ac) | Voltage and Frequency Independent,Voltage and Frequency Dependent |
Modular UPS | No |
Number of Normal Modes | Multiple-normal-mode |
Default Normal Mode (ac) | Voltage and Frequency Independent |
Test Input Voltage (V rms) | 230 |
Test Input Frequency (Hz) | 50 |
Test Output Voltage (V) | 230 |
Test Output Frequency (Hz) | 50 |
Total Input Power in W at 0% Load Min Config Lowest Dependency (ac) | 21 |
Total Input Power in W at 0% Load Min Config Highest Dependency (ac) | 19 |
Efficiency at 25% Load Min Config Lowest Dependency (ac) | 88 |
Efficiency at 25% Load Min Config Highest Dependency (ac) | 96 |
Efficiency at 50% Load Min Config Lowest Dependency (ac) | 91 |
Efficiency at 50% Load Min Config Highest Dependency (ac) | 98 |
Efficiency at 75% Load Min Config Lowest Dependency (ac) | 91 |
Efficiency at 75% Load Min Config Highest Dependency (ac) | 98 |
Efficiency at 100% Load Min Config Lowest Dependency (ac) | 91 |
Efficiency at 100% Load Min Config Highest Dependency (ac) | 99 |
Weighted Efficiency Calc Min Config Lowest Dependency | 91 |
Weighted Efficiency Calc Min Config Highest Dependency | 98 |
Minimum Configuration Input Power Factor Lowest-Input Dependency | 1 |
Minimum Configuration Input Power Factor Highest-Input Dependency | 1 |
Efficiency (%) | 91 |
Modular UPS Module Tested Model Number | N/A |
Energy Storage Mechanism | Battery |
Energy Storage System Technology | Valve Regulated Lead-acid Battery |
Energy Storage System Configuration | Separate Enclosure |
Energy Storage System Removable to Another Room | No |
Energy Storage System Runtime at 100% Load (min.) | 2 |
Energy Storage System Runtime at 50% Load (min.) | 4 |
Energy Storage System Warranty (yrs) | 2 |
Energy Storage System Information URL | http://www.enersys.com/ http://www.eastpennunigy.com/ |
Network Connections Available | USB Port,Ethernet |
Communication Protocols | HTTP |
Manufacturer Take Back Program | No |
Model Web Page URL | https://www.vertivco.com/en-us/products-catalog/critical-power/uninterruptible-power-supplies-ups/ |
Test Method Guidelines | N/A |
Date Qualified | September 18, 2020 |
Compare Vertiv - ITA-01k00AS1102C00 With Other 94 Models
- ITA-01k00AS1102C00 vs EXS 0040kTH16FN01000
- ITA-01k00AS1102C00 vs EXS 0060kTK16FN01000
- ITA-01k00AS1102C00 vs GXE-06k00TL1102C00
- ITA-01k00AS1102C00 vs GXE-10k00TLA102C00
- ITA-01k00AS1102C00 vs GXE-20k00TL3302C00
- ITA-01k00AS1102C00 vs GXT5-3000LVRT2UXL
- ITA-01k00AS1102C00 vs GXT5-2000LVRT2UXL
- ITA-01k00AS1102C00 vs GXT5-1500LVRT2UXL
- ITA-01k00AS1102C00 vs GXT5-1000LVRT2UXL
- ITA-01k00AS1102C00 vs GXT5-6000MVRT4UXLN