Compare Pure Storage – FlashArray//CR4 vs Pure Storage – FlashArray//E Specifications

FlashArray//CR4 FlashArray//E
ENERGY STAR Partner
Pure Storage, Inc. Pure Storage, Inc.
Brand Name
Pure Storage Pure Storage
Model Name
FlashArray//CR4 FlashArray//E
Model Number
FlashArray//CR4 FlashArray//E
Additional Model Information
FlashArray//C50R4,,; FlashArray//C70R4,,; FlashArray//C90R4,, N/A
SNIA Online Taxonomy Category
NVSS Disk Set Online 4 NVSS Disk Set Online 4
Storage Controller Implementation
Scale-Up Storage Scale-Up Storage
Storage Controller Manufacturer Name
Pure Storage Pure Storage
Storage Controller Model Name
FlashArray//C90R4 FlashArray//E
Storage Controller Model Number
FlashArray//C90R4 FlashArray//E
Storage Controller Advanced Data Recovery Type
RAID RAID
Capacity Optimizing Methods (COMs)
Delta Snapshots,Thin Provisioning,Compression,Data Deduplication Delta Snapshots,Thin Provisioning,Compression,Data Deduplication
Workload Optimization Type
Transaction Streaming
Automated Storage Tiering Capable
No No
Software Operating Environment Name
Purity Purity
Software Operating Environment Version
6.4.10 6.6.2
Active or Passive Cooling Enabled in Hardware on Shipment
Both Both
Length of Rolling Average for Input Power (s)
- 0
Length of Rolling Average for Inlet Air Temperature (s)
- 0
Trans Model Number or Config ID
FlashArray//C90R4 N/A
Trans Power Supply Unit (PSU) Type
Single-Output N/A
Trans PSU Manufacturer Name
Delta N/A
Trans PSU Model Name
DPS-1600AB-13 U N/A
Trans PSU Model Number
DPS-1600AB-13 U N/A
Trans PSU Rated Output (W)
1,600 N/A
Trans PSUs 80PLUS Certification
Platinum N/A
Trans Total Amount of Cache (GB)
2,000 N/A
Trans Devices Used for Cache
DRAM N/A
Trans Total Num Installed Storage Devices Optimal Point
20 DFMcs N/A
Trans Num of Controllers in Optimal Point
1 N/A
Trans Num Redundant Controllers Optimal Point
0 N/A
Trans Number of PSUs Optimal Point
2 N/A
Trans Number of Redundant PSUs Optimal Point
2 N/A
Trans Auto Tiering Enabled Optimal Point
No N/A
Trans Optimal Point Hot Band Workload Test (IOPS/W)
30 N/A
Trans Optimal Point Random Read Workload Test (IOPS/W)
56 N/A
Trans Optimal Point Random Write Workload Test (IOPS/W)
112 N/A
Trans Optimal Point Ready Idle Workload Test (GB/W)
2,101 N/A
Date Available On Market
June 14, 2023 June 14, 2023
Date Qualified
December 1, 2023 February 29, 2024
Markets
United States, Canada United States, Canada
CB Model Identifier
ES_1132228_FlashArray//CR4_112920232142193_5875438 ES_1132228_FlashArray//E_020620242201765_1267330
Product Category
Data Center Storage Data Center Storage
Type
Data Center Storage Data Center Storage
Date Certified
December 1, 2023 February 29, 2024
Meets ENERGY STAR Most Efficient 2024 Criteria
No No

Compare Pure Storage - FlashArray//CR4 With Other 6 Models

Scroll to Top