Introducing the Emerson SOLAHD S4K2U3000D, a state-of-the-art Ac-output UPS designed for the modern consumer.
This model, S4K2U3000D, is part of the ENERGY STAR certified products and is brought to you by Appleton Grp LLC d/b/a Appleton Group.
Key Features:
- Date Available On Market: January 1, 2024
- Date Certified: October 31, 2023
- Markets: United States, Canada
- CB Model Identifier: ES_1129526_S4K2U3000D_103120231742756_7362427
- Meets ENERGY STAR Most Efficient 2024 Criteria: No
- Application: Commercial
Available in United States, Canada markets, the Emerson SOLAHD S4K2U3000D is the perfect addition to any home, offering both performance and energy efficiency.
Release Date: January 1, 2024 Qualified Date: October 31, 2023
Don't miss out on this high-performance, energy-efficient Ac-output UPS.
Get yours today and enjoy the ultimate viewing experience!
More on S4K2U3000D
Full Specifications of S4K2U3000D
Specification
| ENERGY STAR Partner | Appleton Grp LLC d/b/a Appleton Group |
| Product Category | Uninterruptible Power Supplies |
| Type | Ac-output UPS |
| Brand Name | Emerson |
| Model Name | SOLAHD S4K2U3000D |
| Model Number | S4K2U3000D |
| Date Available On Market | January 1, 2024 |
| Date Certified | October 31, 2023 |
| Markets | United States, Canada |
| CB Model Identifier | ES_1129526_S4K2U3000D_103120231742756_7362427 |
| Meets ENERGY STAR Most Efficient 2024 Criteria | No |
| Power Conversion Mechanism | Static |
| Minimum Configuration Tested Model Number | S4K2U3000D |
| Active Output Power Rating Minimum Configuration (W) | 2,700 |
| Apparent Output Power Rating Minimum Configuration (VA) | 3,000 |
| Topology (ac) | Double Conversion |
| Topology and Product Type Combined | ac - Double Conversion (VFI) |
| Application | Commercial |
| Rated Input Voltage (V rms) | 110-125 |
| Rated Input Frequency (Hz) | 50-60 |
| Rated Output Voltage (V) | 110-125 |
| Rated Output Frequency (Hz) | 50-60 |
| Rack Mountable | Yes |
| Height (mm) | 85 |
| Width (mm) | 430 |
| Depth (mm) | 627 |
| Normal Mode(s) Input Dependency Characteristic (ac) | Voltage and Frequency Independent |
| Modular UPS | No |
| Number of Normal Modes | Single-normal-mode |
| Default Normal Mode (ac) | Voltage and Frequency Independent |
| Test Input Voltage (V rms) | 120 |
| Test Input Frequency (Hz) | 60 |
| Test Output Voltage (V) | 120 |
| Test Output Frequency (Hz) | 60 |
| Total Input Power in W at 0% Load Min Config Lowest Dependency (ac) | 43 |
| Efficiency at 25% Load Min Config Lowest Dependency (ac) | 92 |
| Efficiency at 50% Load Min Config Lowest Dependency (ac) | 94 |
| Efficiency at 75% Load Min Config Lowest Dependency (ac) | 94 |
| Efficiency at 100% Load Min Config Lowest Dependency (ac) | 93 |
| Weighted Efficiency Calc Min Config Lowest Dependency | 94 |
| Efficiency (%) | 94 |
| Modular UPS Module Tested Model Number | N/A |
| Energy Storage Mechanism | Battery |
| Energy Storage System Technology | Valve Regulated Lead-acid Battery |
| Energy Storage System Configuration | Integral |
| Energy Storage System Removable to Another Room | No |
| Energy Storage System Runtime at 100% Load (min.) | 4 |
| Energy Storage System Runtime at 50% Load (min.) | 13 |
| Energy Storage System Warranty (yrs) | 2 |
| Energy Storage System Information URL | www.appleton.emerson.com/en-us/electrical-components-lighting/power-quality-distribution |
| Network Connections Available | Serial Port,Other,Ethernet,USB Port |
| Communication Protocols | HTTP,HTTPS,Other,Modbus TCP,SNMP (v1, 2 or 3),Modbus RTU |
| Manufacturer Take Back Program | Yes |
| Model Web Page URL | https://www.appleton.emerson.com/en-us/electrical-components-lighting/power-quality-distribution |
| Test Method Guidelines | N/A |
| Date Qualified | October 31, 2023 |