Introducing the Tripp Lite AGPS8296, a state-of-the-art Ac-output UPS designed for the modern consumer.
This model, SU3000LCD2UHV, is part of the ENERGY STAR certified products and is brought to you by Eaton Corporation.
Key Features:
- Date Available On Market: July 24, 2015
- Date Certified: August 17, 2015
- Markets: United States, Canada
- CB Model Identifier: ES_1097458_SU3000LCD2UHV_03112019114354_3621167
- Meets ENERGY STAR Most Efficient 2024 Criteria: No
- Application: Commercial,Consumer
Available in United States, Canada markets, the Tripp Lite AGPS8296 is the perfect addition to any home, offering both performance and energy efficiency.
Release Date: July 24, 2015 Qualified Date: August 17, 2015
Don't miss out on this high-performance, energy-efficient Ac-output UPS.
Get yours today and enjoy the ultimate viewing experience!
More on SU3000LCD2UHV
Full Specifications of SU3000LCD2UHV
Specification
| ENERGY STAR Partner | Eaton Corporation |
| Product Category | Uninterruptible Power Supplies |
| Type | Ac-output UPS |
| Brand Name | Tripp Lite |
| Model Name | AGPS8296 |
| Model Number | SU3000LCD2UHV |
| Date Available On Market | July 24, 2015 |
| Date Certified | August 17, 2015 |
| Markets | United States, Canada |
| CB Model Identifier | ES_1097458_SU3000LCD2UHV_03112019114354_3621167 |
| Meets ENERGY STAR Most Efficient 2024 Criteria | No |
| Power Conversion Mechanism | Static |
| Minimum Configuration Tested Model Number | AGPS8296 |
| Active Output Power Rating Minimum Configuration (W) | 2,700 |
| Apparent Output Power Rating Minimum Configuration (VA) | 2,700 |
| Topology (ac) | Multi-Mode Double Conversion |
| Topology and Product Type Combined | ac - Other |
| Application | Commercial,Consumer |
| Rated Input Voltage (V rms) | 200-240 |
| Rated Input Frequency (Hz) | 50-60 |
| Rated Output Voltage (V) | 200-240 |
| Rated Output Frequency (Hz) | 50-60 |
| Rack Mountable | Yes |
| Rack Mount Height (U) | 2 |
| Height (mm) | 88 |
| Width (mm) | 438 |
| Depth (mm) | 616 |
| Total Number of Outlets | 8 |
| Number of Battery Backup and Surge Protected Outlets | 8 |
| Number of Surge Protected Only Outlets | 0 |
| Normal Mode(s) Input Dependency Characteristic (ac) | Voltage and Frequency Dependent,Voltage and Frequency Independent |
| Modular UPS | No |
| Number of Normal Modes | Multiple-normal-mode |
| Default Normal Mode (ac) | Voltage and Frequency Dependent |
| Test Input Voltage (V rms) | 240 |
| Test Input Frequency (Hz) | 60 |
| Test Output Voltage (V) | 240 |
| Test Output Frequency (Hz) | 60 |
| Total Input Power in W at 0% Load Min Config Lowest Dependency (ac) | 1 |
| Total Input Power in W at 0% Load Min Config Highest Dependency (ac) | 1 |
| Efficiency at 25% Load Min Config Lowest Dependency (ac) | 89 |
| Efficiency at 25% Load Min Config Highest Dependency (ac) | 92 |
| Efficiency at 50% Load Min Config Lowest Dependency (ac) | 92 |
| Efficiency at 50% Load Min Config Highest Dependency (ac) | 96 |
| Efficiency at 75% Load Min Config Lowest Dependency (ac) | 93 |
| Efficiency at 75% Load Min Config Highest Dependency (ac) | 97 |
| Efficiency at 100% Load Min Config Lowest Dependency (ac) | 93 |
| Efficiency at 100% Load Min Config Highest Dependency (ac) | 98 |
| Weighted Efficiency Calc Min Config Lowest Dependency | 93 |
| Weighted Efficiency Calc Min Config Highest Dependency | 97 |
| Minimum Configuration Input Power Factor Lowest-Input Dependency | 1 |
| Minimum Configuration Input Power Factor Highest-Input Dependency | 1 |
| Efficiency (%) | 94 |
| Modular UPS Module Tested Model Number | N/A |
| Energy Storage Mechanism | Battery |
| Energy Storage System Technology | Valve Regulated Lead-acid Battery |
| Energy Storage System Configuration | Integral |
| Energy Storage System Removable to Another Room | No |
| Energy Storage System Runtime at 100% Load (min.) | 5 |
| Energy Storage System Runtime at 50% Load (min.) | 14 |
| Energy Storage System Warranty (yrs) | 3 |
| Energy Storage System Information URL | N/A |
| Battery Recycling URL | http://www.tripplite.com/en/support/recycling-program.cfm |
| Network Connections Available | Serial Port,USB Port,Ethernet |
| Communication Protocols | None |
| Manufacturer Take Back Program | Yes |
| Manufacturer Take Back Program URL | http://www.tripplite.com/en/support/recycling-program.cfm |
| Model Web Page URL | https://www.tripplite.com/smartonline-208-240v-3kva-2.7kw-double-conversion-ups-2u-extended-run-snmp-card-option-lcd-usb-db9-energy-star~SU3000LCD2UHV |
| Test Method Guidelines | N/A |
| Date Qualified | August 17, 2015 |
Compare Tripp Lite - SU3000LCD2UHV With Other 10 Models
- SU3000LCD2UHV vs SUINT3000LCD2U
- SU3000LCD2UHV vs SUINT1000LCD2U
- SU3000LCD2UHV vs SUINT2200LCD2U
- SU3000LCD2UHV vs ECO1000LCD
- SU3000LCD2UHV vs SU3000RTXLCD3U
- SU3000LCD2UHV vs ECO650UPSM
- SU3000LCD2UHV vs SUINT1500LCD2U
- SU3000LCD2UHV vs ECO750UPS
- SU3000LCD2UHV vs SU2000RTXLCD2U
- SU3000LCD2UHV vs ECO900UPSM
Related Models - SU3000LCD2UHV Alternative
- Tripp Lite SUINT3000LCD2U
- Tripp Lite SUINT1000LCD2U
- Tripp Lite SUINT2200LCD2U
- Tripp Lite ECO1000LCD
- Tripp Lite SU3000RTXLCD3U
- Tripp Lite ECO650UPSM
- Tripp Lite SUINT1500LCD2U
- Tripp Lite ECO750UPS
- Tripp Lite SU2000RTXLCD2U
- Tripp Lite ECO900UPSM